Original Research


DOI :10.26650/eor.20210065   IUP :10.26650/eor.20210065    Full Text (PDF)

Diagnostic accuracy of endoscopy for the detection of isthmuses of mandibular molar teeth using micro-CT as reference

Ali KeleşCangül KeskinRawan AlqawasmiKaan GündüzHikmet Aydemir

Purpose The aim of this study was to evaluate the efficacy of endoscopic visualisation to detect the presence and type of isthmuses within the mesial root canals of mandibular first molar teeth compared with micro-computed tomography (microCT) images as reference. Materials and Methods Thirty-two mesial roots of mandibular first molars presenting isthmuses were selected based on micro-CT scans. In all, 12 type I and 20 band-shaped isthmuses were collected. The specimens were mounted in the posterior socket of dental phantom manikin for endoscopic visualisation. The ability of endoscopes to visualize the presence of isthmuses and distinguish the type of isthmuses was compared. Micro-CT images of the specimens were used as references. Data were analyzed using Fisher’s exact tests. Results Sensitivity of endoscope to detect isthmuses were also calculated for each isthmus type. In 37.5% of the samples, isthmus presence was correctly diagnosed via orthograde endoscopic visualization. Type I istmuses were significantly more detected than band-shaped isthmuses (P<0.05). Endoscope showed higher sensitivity to detect type I isthmus than band-shaped isthmus. Conclusion The endodontic endoscope could detect type I isthmuses more accurately than band- shaped isthmuses.


PDF View

References

  • 1. Marceliano–Alves MF, Lima CO, Nayre-Bastos PM, Bruno AM, Vidaurre F, Coutinho TM, Fidel SR, Lopes RT. Mandibular mesial root canal morphology using micro–computed tomography in a Brazilian population. Aust Endod J 2019;45:51-6. [CrossRef] google scholar
  • 2. Martins JNR, Marques D, Silva EJNL, Caramês J, Versiani MA. Prevalence studies on root canal anatomy using cone-beam computed tomographic imaging: a systematic review. J Endod 2019;45:372-86. [CrossRef] google scholar
  • 3. Keleş A, Keskin C. A micro–computed tomographic study of band–shaped root canal isthmuses, having their floor in the apical third of mesial roots of mandibular first molars. Int Endod J 2018;51:240-6. [CrossRef] google scholar
  • 4. Von Arx T. Frequency and type of canal isthmuses in first molars detected by endoscopic inspection during periradicular surgery. Int Endod J 2005;38:160- 8. [CrossRef] google scholar
  • 5. Teixeira FB, Sano CL, Gomes BPFA, Zaia AA, Ferraz CCR, SouzaFilho FJ. A preliminary in vitro study of the incidence and position of the root canal isthmus in maxillary and mandibular first molars. Int Endod J 2003;36:276- 80. [CrossRef] google scholar
  • 6. Fan B, Pan Y, Gao Y, Fang F, Wu Q, Gutmann JL. Three-dimensional morphologic analysis of isthmuses in the mesial roots of mandibular molars. J Endod 2010;36:1866-9. [CrossRef] google scholar
  • 7. Siqueira JF, Alves FR, Versiani MA, Rocas IN, Almeida BM, Neves MA, Sousa-Neto MD. Correlative bacteriologic and micro– computed tomographic analysis of mandibular molar mesial canals prepared by Self-Adjusting File, Reciproc, and Twisted File systems. J Endod 2013;39:1044-50. [CrossRef] google scholar
  • 8. Ordinola–Zapata R, Bramante C, Versiani M, Moldauer BI, Topham G, Gutmann JL, Nunez A, Duarte MA, Abella F. Comparative accuracy of the clearing technique, CBCT and Micro–CT methods in studying the mesial root canal configuration of mandibular first molars. Int Endod J 2017;50:90-6. [CrossRef] google scholar
  • 9. Domark JD, Hatton JF, Benison RP, Hildebolt CF. An ex vivo comparison of digital radiography and cone-beam and micro computed tomography in the detection of the number of canals in the mesiobuccal roots of maxillary molars. J Endod 2013;39:901-5. [CrossRef] google scholar
  • 10. Carr GB, Murgel CA The use of the operating microscope in endodontics. Dent Clin 2010;54:191-214. [CrossRef] google scholar
  • 11. Mendes AB, Soares AJ, Martins JNR, Silva EJNL, Frozoni MR. Influence of access cavity design and use of operating microscope and ultrasonic troughing to detect middle mesial canals in mandibular first molars. Int Endod J 2020; doi:10.1111/ IEJ.13352. [CrossRef] google scholar
  • 12. Khalighinejad N, Aminoshariae A, Kulild JC, Williams KA, Wang J, Mickel A. The effect of the dental operating microscope on the outcome of nonsurgical root canal treatment: a retrospective case-control study. J Endod 2017;43:728- 32. [CrossRef] google scholar
  • 13. Engelke W, Leiva C, Wagner G, Beltrán V. In vitro visualization of human endodontic structures using different endoscope systems. Int J Clin Exp Med 2005;8:3234-40. google scholar
  • 14. Moshonov J, Michaeli E, Nahlieli O. Endoscopic root canal treatment. Quintessence Int 2009;40:739–44. google scholar
  • 15. Keleş A, Keskin C, Alqawasmi R, Aydemir H. Accuracy of an endoscope to detect root canal anastomoses in mandibular molar teeth: a comparative study with micro-computed tomography. Acta Odontol Scand 2020;6:1. [CrossRef] google scholar
  • 16. Silva AA, Belladonna FG, Rover G, Lopes RT, Moreira EJL, DeDeus G, Silva EJNL. Does ultraconservative access effect the efficacy of root canal treatment and the fracture resistance of two-rooted maxillary premolars? Int Endod J 2020;53:265-75. [CrossRef] google scholar
  • 17. Fujimoto M, Okuda M, Yoshii S, Ikezawa S, Toshitsugu U, Tassery H, Cuisinier F, Kitamura C. Endoscopic System Based on Intraoral Camera and Image Processing. IEEE Trans Biomed Eng 2019;66:1026-33. [CrossRef] google scholar
  • 18. Bahcall JK, DiFiore PM, Poulakidas TK. An endoscopic technique for endodontic surgery. J Endod 1999;25:132-5. [CrossRef] google scholar
  • 19. Detsch SG, Cunningham WT, Langloss JM. Endoscopy as an aid to endodontic diagnosis. J Endod 1979;5:60-2. [CrossRef] google scholar
  • 20. Tolentino ES, Amoroso-Silva PA, Alcalde MP, Honorio HM, Iwaki LCV, Rubira-Bullen IRF, Hungaro-Duarte MA. Accuracy of high resolution small- volume cone-beam computed tomography in detecting complex anatomy of the apical isthmi: ex vivo analysis. J Endod 2018;44:1862-6. [CrossRef] google scholar
  • 21. Tolentino ES, Amoroso-Silva PA, Alcalde MP, Honorio HM, Iwaki LCV, Rubira-Bullen IRF, Hungaro-Duarte MA. Limitation of diagnostic value of cone-beam CT in detecting apical root isthmuses. J Appl Oral Sci 2020;27;28:e20190168. [CrossRef] google scholar
  • 22. Hu X, Huang Z, Huang Z, Lei L, Cui M, Zhang X. Presence of isthmi in mandibular mesial roots and associated factors: an in vivo analysis. Surg Radiol Anat 2019;41:815-22. [CrossRef] google scholar
  • 23. Gani OA, Boiero CF, Correa C, Masin I, Machado R, Silva EJ, Vansan LP. Morphological changes related to age in mesial root canals of permanent mandibular first molars. Acta Odontol Latinoam 2014;27:105-9. google scholar
  • 24. Estrela C, Rabelo LE, de Souza JB, Alencar AH, Estrela CR, Sousa Neto MD, Pecora JD. Frequency of root canal isthmi in human permanent teeth determined by cone-beam computed tomography. J Endod 2015;41:1535-9. [CrossRef] google scholar

Citations

Copy and paste a formatted citation or use one of the options to export in your chosen format


EXPORT



APA

Keleş, A., Keskin, C., Alqawasmi, R., Gündüz, K., & Aydemir, H. (2021). Diagnostic accuracy of endoscopy for the detection of isthmuses of mandibular molar teeth using micro-CT as reference. European Oral Research, 55(1), 34-38. https://doi.org/10.26650/eor.20210065


AMA

Keleş A, Keskin C, Alqawasmi R, Gündüz K, Aydemir H. Diagnostic accuracy of endoscopy for the detection of isthmuses of mandibular molar teeth using micro-CT as reference. European Oral Research. 2021;55(1):34-38. https://doi.org/10.26650/eor.20210065


ABNT

Keleş, A.; Keskin, C.; Alqawasmi, R.; Gündüz, K.; Aydemir, H. Diagnostic accuracy of endoscopy for the detection of isthmuses of mandibular molar teeth using micro-CT as reference. European Oral Research, [Publisher Location], v. 55, n. 1, p. 34-38, 2021.


Chicago: Author-Date Style

Keleş, Ali, and Cangül Keskin and Rawan Alqawasmi and Kaan Gündüz and Hikmet Aydemir. 2021. “Diagnostic accuracy of endoscopy for the detection of isthmuses of mandibular molar teeth using micro-CT as reference.” European Oral Research 55, no. 1: 34-38. https://doi.org/10.26650/eor.20210065


Chicago: Humanities Style

Keleş, Ali, and Cangül Keskin and Rawan Alqawasmi and Kaan Gündüz and Hikmet Aydemir. Diagnostic accuracy of endoscopy for the detection of isthmuses of mandibular molar teeth using micro-CT as reference.” European Oral Research 55, no. 1 (Apr. 2024): 34-38. https://doi.org/10.26650/eor.20210065


Harvard: Australian Style

Keleş, A & Keskin, C & Alqawasmi, R & Gündüz, K & Aydemir, H 2021, 'Diagnostic accuracy of endoscopy for the detection of isthmuses of mandibular molar teeth using micro-CT as reference', European Oral Research, vol. 55, no. 1, pp. 34-38, viewed 23 Apr. 2024, https://doi.org/10.26650/eor.20210065


Harvard: Author-Date Style

Keleş, A. and Keskin, C. and Alqawasmi, R. and Gündüz, K. and Aydemir, H. (2021) ‘Diagnostic accuracy of endoscopy for the detection of isthmuses of mandibular molar teeth using micro-CT as reference’, European Oral Research, 55(1), pp. 34-38. https://doi.org/10.26650/eor.20210065 (23 Apr. 2024).


MLA

Keleş, Ali, and Cangül Keskin and Rawan Alqawasmi and Kaan Gündüz and Hikmet Aydemir. Diagnostic accuracy of endoscopy for the detection of isthmuses of mandibular molar teeth using micro-CT as reference.” European Oral Research, vol. 55, no. 1, 2021, pp. 34-38. [Database Container], https://doi.org/10.26650/eor.20210065


Vancouver

Keleş A, Keskin C, Alqawasmi R, Gündüz K, Aydemir H. Diagnostic accuracy of endoscopy for the detection of isthmuses of mandibular molar teeth using micro-CT as reference. European Oral Research [Internet]. 23 Apr. 2024 [cited 23 Apr. 2024];55(1):34-38. Available from: https://doi.org/10.26650/eor.20210065 doi: 10.26650/eor.20210065


ISNAD

Keleş, Ali - Keskin, Cangül - Alqawasmi, Rawan - Gündüz, Kaan - Aydemir, Hikmet. Diagnostic accuracy of endoscopy for the detection of isthmuses of mandibular molar teeth using micro-CT as reference”. European Oral Research 55/1 (Apr. 2024): 34-38. https://doi.org/10.26650/eor.20210065



TIMELINE


Submitted05.06.2020
Accepted02.11.2020
Published Online31.01.2021

LICENCE


Attribution-NonCommercial (CC BY-NC)

This license lets others remix, tweak, and build upon your work non-commercially, and although their new works must also acknowledge you and be non-commercial, they don’t have to license their derivative works on the same terms.


SHARE




Istanbul University Press aims to contribute to the dissemination of ever growing scientific knowledge through publication of high quality scientific journals and books in accordance with the international publishing standards and ethics. Istanbul University Press follows an open access, non-commercial, scholarly publishing.