Research Article


DOI :10.26650/eor.20210110   IUP :10.26650/eor.20210110    Full Text (PDF)

Dimensional accuracy of vinyl polyether and polyvinyl siloxane impression materials in direct implant impression technique for multiple dental implants

Rohini RajendranN. Gopi ChanderKuttae Vishwanathan AnithaBalasubramanian Muthukumar

Purpose The present study compared the dimensional accuracy of vinyl polyether silicone (VPES) and polyvinyl siloxane (PVS) impression materials used for non-splinted (NS) and splinted (S) direct open-tray impression techniques for multiple implants inserted in simulated edentulous mandibles. Materials and Methods A mandibular stainless steel model with eight internal connections for implant analogs was fabricated to simulate a clinical scenario. The acrylic resin splinted and non-splinted direct impressions were obtained for both VPES and PVS materials. Seventy-two cast samples were divided into four groups based on the impression techniques and materials used. The dimensional accuracies of the casts were measured in three different axes using a computerized coordinate measuring machine (CMM), and were statistically compared. Results The differences in the distortion values between the VPES and PVS impression materials were not statistically significant. Similarly, the differences between the splinted and non-splinted groups among the VPES and PVS materials were not statistically significant. Conclusion The casts fabricated from VPS or PVS impression materials provide similar dimensional accuracy regardless of the implant splinting method. 


PDF View

References

  • 1. Buser D, Janner SF, Wittneben JG, Bragger U, Ramseier CA, Salvi GE. 10-year survival and success rates of 511 titanium implants with a sandblasted and acid-etched surface: a retrospective study in 303 partially edentulous patients. Clin Implant Dent Relat Res 2012;14:839-51. [CrossRef] google scholar
  • 2. Ravald N, Dahlgren S, Teiwik A, Gröndahl K. Long-term evaluation of Astra Tech and Brânemark implants in patients treated with full-arch bridges. Results after 12-15 years. Clin Oral Implants Res 2013;24:1144-51. [CrossRef] google scholar
  • 3. Arora A, Upadhyaya V, Parashar KR, Malik D. Evaluation of the effect of implant angulations and impression techniques on implant cast accuracy - An in vitro study. J Indian Prosthodont Soc 2019;19:149-58. [CrossRef] google scholar
  • 4. Bhakta S, Vere J, Calder I, Patel R. Impressions in implant dentistry. Br Dent J 2011;211:361-7. [CrossRef] google scholar
  • 5. Yokoyama S, Wakabayashi N, Shiota M, Ohyama T. Stress analysis in edentulous mandibular bone supporting implant-retained 1-piece or multiple superstructures. Int J Oral Maxillofac Implants 2005;20:578-83. google scholar
  • 6. Balamurugan T, Manimaran P. Evaluation of accuracy of direct transfer snapon impression coping closed tray impression technique and direct transfer open tray impression technique: an in vitro study. J Indian Prosthodont Soc 2013;13:226-32. [CrossRef] google scholar
  • 7. Al Quran FA, Rashdan BA, Zomar AA, Weiner S. Passive fit and accuracy of three dental implant impression techniques. Quintessence Int 2012;43:119-25. google scholar
  • 8. Abduo J, Bennani V, Waddell N, Lyons K, Swain M. Assessing the fit of implant fixed prostheses: a critical review. Int J Oral Maxillofac Implants 2010;25:506-15. google scholar
  • 9. Ender A, Mehl A. Accuracy of complete-arch dental impressions: a new method of measuring trueness and precision. J Prosthet Dent 2013;109:121-28. [CrossRef] google scholar
  • 10. Al-Abdullah K, Zandparsa R, Finkelman M, Hirayama H. An in vitro comparison of the accuracy of implant impressions with coded healing abutments and different implant angulations. J Prosthet Dent 2013;110:90-100. [CrossRef] google scholar
  • 11. Baig MR, Buzayan MM, Yunus N. Accuracy of a new elastomeric impression material for complete-arch dental implant impressions. J Investig Clin Dent 2018;9:e12320. [CrossRef] google scholar
  • 12. Siadat H, Saeidi Z, Alikhasi M, Zeighami S. Comparative evaluation of the effect of impression materials and trays on the accuracy of angulated implants impressions. J Clin Exp Dent 2018;10:e1096-102. [CrossRef] google scholar
  • 13. Saini HS, Jain S, Kumar S, Aggarwal R, Choudhary S, Reddy NK. Evaluating the Effect of Different Impression Techniques and Splinting Methods on the Dimensional Accuracy of Multiple Implant Impressions: An in vitro Study. J Contemp Dent Pract 2018;19:1005-12. [CrossRef] google scholar
  • 14. Conrad HJ, Pesun IJ, DeLong R, Hodges JS. Accuracy of two impression techniques with angulated implants. J Prosthet Dent 2007;97:349-56. [CrossRef] google scholar
  • 15. Baig MR. Accuracy of impressions of multiple implants in the edentulous arch: a systematic review. Int J Oral Maxillofac Implants 2014;29:869-80. [CrossRef] google scholar
  • 16. Izadi A, Heidari B, Roshanaei G, Allahbakhshi H, Fotovat F. Comparative Study of Dimensional Accuracy in Three Dental Implant Impression Techniques: Open Tray, Closed Tray with Impression Coping, and Snap Cap. J Contemp Dent Pract 2018;19:974-81. [CrossRef] google scholar
  • 17. Kurtulmus-Yilmaz S, Ozan O, Ozcelik TB, Yagiz A. Digital evaluation of the accuracy of impression techniques and materials in angulated implants. J Dent 2014;42:1551-59. [CrossRef] google scholar
  • 18. Herbst D, Nel JC, Driessen CH, Becker PJ. Evaluation of impression accuracy for osseointegrated implant supported superstructures. J Prosthet Dent 2000;83:555-61. [CrossRef] google scholar
  • 19. Assuncao WG, Filho HG, Zaniquelli O. Evaluation of transfer impressions for osseointegrated implants at various angulations. Implant Dent 2004;13:358-66. [CrossRef] google scholar
  • 20. Papaspyridakos P, Benic GI, Hogsett VL, White GS, Lal K, Gallucci GO. Accuracy of implant casts generated with splinted and non-splinted impression techniques for edentulous patients: An optical scanning study. Clin Oral Implants Res 2012;23:676-81. [CrossRef] google scholar
  • 21. Naconecy MM, Teixeira ER, Shinkai RS, Frasca LC, Cervieri A. Evaluation of the accuracy of 3 transfer techniques for implant-supported prostheses with multiple abutments. Int J Oral Maxillofac Implants 2004;19:192-98. google scholar
  • 22. Kim S, Nicholls JI, Han CH, Lee KW. Displacement of implant components from impressions to definitive casts. Int J Oral Maxillofac Implants 2006;21:747-55. google scholar
  • 23. Pera F, Pesce P, Bevilacqua M, Setti P, Menini M. Analysis of different impression techniques and materials on multiple implants through 3-dimensional laser scanner. Implant Dent 2016;25:232-37. [CrossRef] google scholar
  • 24. Nakhaei M, Madani AS, Moraditalab A, Haghi HR. Three-dimensional accuracy of different impression techniques for dental implants. Dent Res J (Isfahan) 2015;12:431-37. [CrossRef] google scholar
  • 25. Walker MP, Alderman N, Petrie CS, Melander J, McGuire J. Correlation of impression removal force with elastomeric impression material rigidity and hardness. J Prosthodont 2013;22:362-66. [CrossRef] google scholar
  • 26. de Avila ED, Barros LA, Del’Acqua MA, Castanharo SM, Mollo Fde A Jr. Comparison of the accuracy for three dental impression techniques and index: an in vitro study. J Prosthodont Res 2013;57:268-74. [CrossRef] google scholar
  • 27. Alexander Hazboun GB, Masri R, Romberg E, Kempler J, Driscoll CF. Effect of implant angulation and impression technique on impressions of Nobel Active implants. J Prosthet Dent 2015;113:425-31. [CrossRef] google scholar
  • 28. Selvaraj S, Dorairaj J, Mohan J, Simon P. Comparison of implant cast accuracy of multiple implant impression technique with different splinting materials: An in vitro study. J Indian Prosthodont Soc 2016;16:167-75. [CrossRef] google scholar
  • 29. Haghi HR, Shiehzadeh M, Nakhaei M, Ahrary F, Sabzevari S. Effect of technique and impression material on the vertical misfit of a screw-retained, three-unit implant bridge: An in vitro study. J Indian Prosthodont Soc 2017;17:41-7. [CrossRef] google scholar
  • 30. Joseph TM, Ravichandran R, Lylajam S, Viswabharan P, Janardhanan K, Rajeev S. Evaluation of positional accuracy in multiple implants using four different splinting materials: An in vitro study. J Indian Prosthodont Soc 2018;18:239-47. [CrossRef] google scholar
  • 31. Tabesh M, Alikhasi M, Siadat H. A Comparison of implant impression precision: Different materials and techniques. J Clin Exp Dent 2018;10:e151-7. google scholar
  • 32. Vojdani M, Torabi K, Ansarifard E. Accuracy of different impression materials in parallel and nonparallel implants. Dent Res J (Isfahan) 2015;12:315-22. [CrossRef] google scholar
  • 33. Ongül D, Gökçen-Röhlig B, Şermet B, Keskin H. A comparative analysis of the accuracy of different direct impression techniques for multiple implants. Aust Dent J 2012;57:184-9. [CrossRef] google scholar
  • 34. Hariharan R, Shankar C, Rajan M, Baig MR, Azhagarasan NS. Evaluation of accuracy of multiple dental implant impressions using various splinting materials. Int J Oral Maxillofac Implants 2010;25:38-44. google scholar
  • 35. Kim JH, Kim KR, Kim S. Critical appraisal of implant impression accuracies: A systematic review. J Prosthet Dent 2015;114:185-92. [CrossRef] google scholar
  • 36. Ebadian B, Rismanchian M, Dastgheib B, Bajoghli F. Effect of different impression materials and techniques on the dimensional accuracy of implant definitive casts. Dent Res J (Isfahan) 2015;12:136-43. google scholar

Citations

Copy and paste a formatted citation or use one of the options to export in your chosen format


EXPORT



APA

Rajendran, R., Chander, N.G., Anitha, K.V., & Muthukumar, B. (2021). Dimensional accuracy of vinyl polyether and polyvinyl siloxane impression materials in direct implant impression technique for multiple dental implants. European Oral Research, 55(2), 54-59. https://doi.org/10.26650/eor.20210110


AMA

Rajendran R, Chander N G, Anitha K V, Muthukumar B. Dimensional accuracy of vinyl polyether and polyvinyl siloxane impression materials in direct implant impression technique for multiple dental implants. European Oral Research. 2021;55(2):54-59. https://doi.org/10.26650/eor.20210110


ABNT

Rajendran, R.; Chander, N.G.; Anitha, K.V.; Muthukumar, B. Dimensional accuracy of vinyl polyether and polyvinyl siloxane impression materials in direct implant impression technique for multiple dental implants. European Oral Research, [Publisher Location], v. 55, n. 2, p. 54-59, 2021.


Chicago: Author-Date Style

Rajendran, Rohini, and N. Gopi Chander and Kuttae Vishwanathan Anitha and Balasubramanian Muthukumar. 2021. “Dimensional accuracy of vinyl polyether and polyvinyl siloxane impression materials in direct implant impression technique for multiple dental implants.” European Oral Research 55, no. 2: 54-59. https://doi.org/10.26650/eor.20210110


Chicago: Humanities Style

Rajendran, Rohini, and N. Gopi Chander and Kuttae Vishwanathan Anitha and Balasubramanian Muthukumar. Dimensional accuracy of vinyl polyether and polyvinyl siloxane impression materials in direct implant impression technique for multiple dental implants.” European Oral Research 55, no. 2 (May. 2024): 54-59. https://doi.org/10.26650/eor.20210110


Harvard: Australian Style

Rajendran, R & Chander, NG & Anitha, KV & Muthukumar, B 2021, 'Dimensional accuracy of vinyl polyether and polyvinyl siloxane impression materials in direct implant impression technique for multiple dental implants', European Oral Research, vol. 55, no. 2, pp. 54-59, viewed 11 May. 2024, https://doi.org/10.26650/eor.20210110


Harvard: Author-Date Style

Rajendran, R. and Chander, N.G. and Anitha, K.V. and Muthukumar, B. (2021) ‘Dimensional accuracy of vinyl polyether and polyvinyl siloxane impression materials in direct implant impression technique for multiple dental implants’, European Oral Research, 55(2), pp. 54-59. https://doi.org/10.26650/eor.20210110 (11 May. 2024).


MLA

Rajendran, Rohini, and N. Gopi Chander and Kuttae Vishwanathan Anitha and Balasubramanian Muthukumar. Dimensional accuracy of vinyl polyether and polyvinyl siloxane impression materials in direct implant impression technique for multiple dental implants.” European Oral Research, vol. 55, no. 2, 2021, pp. 54-59. [Database Container], https://doi.org/10.26650/eor.20210110


Vancouver

Rajendran R, Chander NG, Anitha KV, Muthukumar B. Dimensional accuracy of vinyl polyether and polyvinyl siloxane impression materials in direct implant impression technique for multiple dental implants. European Oral Research [Internet]. 11 May. 2024 [cited 11 May. 2024];55(2):54-59. Available from: https://doi.org/10.26650/eor.20210110 doi: 10.26650/eor.20210110


ISNAD

Rajendran, Rohini - Chander, N.Gopi - Anitha, KuttaeVishwanathan - Muthukumar, Balasubramanian. Dimensional accuracy of vinyl polyether and polyvinyl siloxane impression materials in direct implant impression technique for multiple dental implants”. European Oral Research 55/2 (May. 2024): 54-59. https://doi.org/10.26650/eor.20210110



TIMELINE


Submitted05.02.2020
Accepted16.10.2020
Published Online27.05.2021

LICENCE


Attribution-NonCommercial (CC BY-NC)

This license lets others remix, tweak, and build upon your work non-commercially, and although their new works must also acknowledge you and be non-commercial, they don’t have to license their derivative works on the same terms.


SHARE




Istanbul University Press aims to contribute to the dissemination of ever growing scientific knowledge through publication of high quality scientific journals and books in accordance with the international publishing standards and ethics. Istanbul University Press follows an open access, non-commercial, scholarly publishing.